Fire Safety Design Company in Bangladesh
VEC is the experienced fire safety company in Bangladesh
VEC has successfully completed a large number (700+ RMG-Factories ) of Fire Safety Assessments under the National Initiative (NI) supported by the International Labour Organization (ILO) & DIFE, which is the highest number of assessments completed by a single enterprise in Bangladesh. VEC is the best in fire safety company in Bangladesh.
Our Fire Safety Design & Drawing Consultancy Services followed in this Assessment
- Document evaluation:
During Best fire Safety Company part of an assessment program checks the documents in the presence of the factory Engineer/representative to check the updated documents based on which the Fire safety Assessment will proceed. Following key documents shall be reviewed:
- Review different licenses (Fire license, Explosive license, Chemical license, etc) availability &validity.
- Review of building approval drawings.
- Review the as-built drawing with floor machine layout to understand the adequacy of the egress route.
- Review the design of fire detection systems, hydrant systems, sprinkler systems, etc.
- Review the records of periodic inspection& testing of Fire detection & fighting systems.
- Review the records or documents of fire training, fire round & fire drill.
- On-spot Data accumulation
During the field visits, auditors collect necessary data as per checklist including sketches, measurements, proper counts, etc. these data collection shall include information on building height, egress route, fire detection system, hydrant or sprinkler system as applicable, combustible material, and storage, utility and equipment, personal elements including evacuation drill, etc.
- Graphical surveillance:
During this part of an inspection, auditors travel every corner of the factory and take sufficient photos of all major issues according to the Assessment report.
Best fire Safety Company Consultancy:
- Centralized Fire detection system Design & Drawing with Schematic Diagram.
- Centralized Fire alarm system Design & Drawing with Schematic Diagram.
- Fire Hydrant System Design & Drawing.
- Machine Layout Plan.
- All maintenance documents.
- All Training documents.
Fire detection & fire alarm system company in Bangladesh:
CONVENTIONAL-WALL-SOUNDER
The CWS100-AV Conventional Wall Sounder VAD forms the core of our EN54-23 modular visual alarm device (VAD) range. The unit can either be used as a standalone conventional device or as an intelligent unit by the addition of a wired module (ALWS-MOD) or wireless module (SGWS-MOD). All devices are weatherproof therefore this combined with the modular approach means the majority of applications can be achieved with very few stock components. The unit is equipped with 3 levels of volume adjustment, high output LED beacon, and 32 recognized tones which can be set via the control equipment or locally at the sounder.
Fire Panel
Call us for Price
Syncro AS is a versatile range of open protocol fire alarm control panels compatible with…
# 2 or 4 loop versions as standard (for 6 – 8 loop versions see DS57) #Larger enclosure available (fits 24A/H SLAs) # Loopless panel option (repeater) # 0, 16, 48, or 96 zone indicators # Option for Enable Control key switch # Fully supports Apollo, Argus Vega & Hochiki protocols # Network up to 64 panels/repeaters # 4 programmable sounder circuits as standard # 5.25 amp power supply to EN54 part 4 # Large graphic display # In built help and alarm information screens # Certified to EN54-2/ EN54-4 # Real time clock # Supports Apollo, Argus Vega, and Hochiki loop powered sounders and beacons # Sensitivity adjustment and Drift Compensation # Stylish enclosure design # Soft-touch tactile buttons # 2 programmable function buttons # 3 programmable front panel mounted LED’s # Improved Front loading Printer (optional) # Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) # Simple Windows® graphical configuration utility.
INTELLIGENT HEAT DETECTOR
Call for Price
The A3500 Intelligent Heat Detector is a point detection device that continuously samples…
The A3500 Intelligent Heat Detector is a point detection device that continuously samples temperature variation in the protected area to provide the earliest warning of a fire condition in areas where traditional smoke detection products are not suitable. This detector forms part of the Altair range of aesthetically pleasing low profile detection and alarm products and is fully compatible with all fire control equipment utilizing the Argus fully digital communication protocol. An integral magnet test facility allows easy activation to verify correct functionality and reporting.
INTELLIGENT INPUT MODULE
Call for Price
The Argus module range provides an ideal solution to the monitoring and control…
The Argus module range provides an ideal solution to the monitoring and control requirements of most fire detection and alarm systems, ranging from small and simple, to large and complex. By utilizing the Argus fully digital communication protocol, reliable and fast operation is achieved even when employing the impressive 240 device loop capacity. A choice of mechanical configurations provides easy integration of the units into a variety of field locations. The VMI100 is mounted on a standard faceplate and can be used with a surface back box or flush-mounted and provides the capability to remotely monitor a single circuit which is monitored for fault and alarm condition, a bi-color LED provides local indication of device status.
INTELLIGENT MULTI-CRITERIA DETECTOR
Call for Price
The A2000 Intelligent Multi-Criteria Detector is a point detection device that continuously…
The A2000 Intelligent Multi-Criteria Detector is a point detection device that continuously samples both the air and the temperature variation in the protected area to provide the earliest warning of a fire condition. Special algorithms utilize information from both the smoke and heat sensing elements to ensure a high level of false alarm rejection without compromising genuine alarm sensing performance. This detector forms part of the Altair range of aesthetically pleasing low profile detection and alarm products and is fully compatible with all fire control equipment utilizing the Argus fully digital communication protocol.
FIRE PROTECTION SYSTEM COMPANY IN BANGLADESH
ARMSTRONG DIESEL DRIVEN
Call for Price
The Series 4600F, drawing on over 100 years of pump design expertise and leadership …
The Series 4600F, drawing on over 100 years of pump design expertise and leadership, is the state of art in Horizontal Split Case pumps. It meets or exceeds the requirements of NFPA and testing laboratories involved in fire protection such as UL, ULC, & FM. The family of pumps capitalizes on the‚ Tilted Parting concept to minimize turbulence at the eye of the impeller by its straight laminar approach, thus maximizing efficiency. The family was designed with the commonality of parts, low installation cost, and ease of maintenance objectives. The pump’s compact sizes are ideally suited for space-saving packages and retrofit applications.
ARMSTRONG ELECTRIC DRIVEN
Call for Price
Electric (50 Hz and 60 Hz) and diesel-driven designs. UL, ULC, and/or FM certified solutions available ..
Armstrong Horizontal Split-case (HSC) fire pumps deploy a tilted parting design, with the casing of each pump split at a 15° angle. This maximizes efficiency by minimizing turbulence at the impeller eye. The angled split also keeps suction and discharge centerlines fully aligned – allowing for easy pre-piping on site. Electric (50 Hz and 60 Hz) and diesel-driven designs. UL, ULC, and/or FM certified solutions available and Performance range: 500 USgpm – 3,000 USgpm
ARMSTRONG JOCKEY PUMP
Call for Price
From basic water supply to the most specific pressure boosting and fire line pressure …
From basic water supply to the most specific pressure boosting and fire line pressure. From basic water supply to the most specific pressure boosting and fire line pressure maintenance applications, Armstrong Series 4700 Vertical MultiStage pumps satisfy all water distribution requirements. The wide pressure range – from 10 psig to 430 psig (0.7 bar to 30 bar) – makes this product well suited for applications such as pressure washing of aircraft, trains, boats, and road vehicles as well as spray washing of industrial parts and electronic components.
FIRE HOSE RACK CABINET
Call for Price
NAFFCO Fire hose racks are designed for use in controlling incipient fire by building occupants…
NAFFCO Fire hose racks are designed for use in controlling incipient fire by building occupant use and conform to NFPA 14 standards for CLASS II service. The Fire Hose Racks are manufactured to comply with UL & FM standards. .
SPRINKLER SYSTEM
Call for Price
A fire sprinkler system is an active fire protection method, consisting of water …
A fire sprinkler system is an active fire protection method, consisting of a water supply system, providing adequate pressure and flow rate to a water distribution piping system, onto which fire sprinklers are connected.
To Know more